Eye / camera control evaluation protocol¶
Status: programme-wide evaluation contract
Date: 2026-09-22
Related: TEST_PLAN.md, DATA_SHARING.md, PAPER_EVIDENCE.md, METRICS.md
This file answers four different questions that must not be collapsed into one benchmark:
- Does the code behave deterministically? — automated CI.
- Does it work on this operating system / computer / camera? — hardware QA.
- Does it work for different people, repeatedly? — human evaluation.
- Can the resulting evidence support a paper claim? — research protocol + ethics/consent gate.
A green CI run is not a usability study. One successful webcam demo is not cross-platform support. A public GitHub test report is not automatically research consent.
Evaluation ladder¶
E0 — pure CI: every relevant PR¶
Who: nobody; fully automated.
Hardware: virtual/runner only.
Paper eligible: yes for software-correctness claims, with provenance.
Run on ordinary CI:
- pure gaze calibration math;
- confidence/fallback policy;
- implicit calibration candidate promotion/rejection;
- display coordinate transforms;
- Head-Pointer mapping/deadzone;
- dwell state machine;
- face-switch hysteresis/hold/refractory;
- Gesture Chords;
- global ACTIVE/PAUSED/FAULTED safety state;
- stale-signal watchdog;
- privacy/schema validators;
- fake camera/MediaPipe adapters;
- fake pointer backends;
- portal D-Bus protocol fakes.
Goal: logic and policy regressions are caught without a camera.
E1 — OS matrix CI: every integration PR¶
Who: automated GitHub-hosted runners.
Hardware: no usable representative webcam; OS/runtime only.
Paper eligible: yes for build/install/platform-contract claims, not human performance.
Minimum matrix where supported:
- Ubuntu/Linux x86_64;
- Windows current hosted runner;
- macOS arm64/current runner;
- existing extra architecture legs where the repository workflow supports them.
Measure/record: - install success; - optional dependency resolution; - lazy import behavior; - tests; - platform backend import/probe; - permission/manifest static assertions; - result schema validation.
Do not claim real camera/pointer usability from E1.
E2 — deterministic synthetic trace replay¶
Who: automated.
Input: checked-in numeric traces with no face images.
Paper eligible: yes as regression/simulation evidence; label it synthetic.
Trace families:
- gaze drift / confidence drop;
- head jitter / motion / loss / recovery;
- dwell enter/reset/fire/re-arm;
- brow/mouth/blink blendshape-like normalized traces;
- talking-like mouth movement;
- face commit + simultaneous head-motion coupling;
- stale timestamps;
- topology change mid-session.
Primary purpose: make failures reproducible.
E3 — one-machine hardware smoke¶
Who: contributor/tester.
Hardware: real camera / OS / compositor.
Paper eligible: engineering evidence; human performance only if a research protocol separately covers the tester.
Scripted duration: approximately 10–20 minutes.
Minimum checks: 1. feature off -> camera unopened; 2. enable -> permission/status correct; 3. calibrate/recenter; 4. perform a small target/switch task; 5. deliberately lose camera/tracking; 6. verify no stale/repeated action; 7. pause/kill; 8. resume/re-arm; 9. disable -> camera released; 10. save privacy-safe result JSON/report.
E4 — cross-computer replication¶
Question: does the same OS/software work on different physical machines/cameras?
For each supported platform/session, collect results on at least: - two different computers; - preferably two camera models/integrated cameras; - at least one non-1.0 display scaling configuration where relevant.
Keep each result separate. Do not average machine latency across unlike hosts.
E5 — cross-person replication¶
Question: does the calibration/control work for different people on comparable hardware?
This is where participant-specific behavior matters: - gaze calibration; - head neutral pose/range; - face-switch threshold; - speech/face coupling; - comfort/fatigue.
If the results are intended for publication as human-participant evidence, E5 must run under the research/ethics and consent process in DATA_SHARING.md and PAPER_EVIDENCE.md.
Community QA reports remain useful even when they are not paper-eligible.
E6 — repeated-session / test-retest¶
Question: is the feature stable over time for the same person/computer?
Recommended: - 3 sessions on different times/days when feasible; - same software/config; - record whether calibration was reused or repeated; - report drift and false actions.
This distinguishes "worked once after calibration" from usable stability.
E7 — controlled human study¶
Only needed for claims about: - task completion; - speed/throughput; - error/false activation across people; - usability; - fatigue/comfort; - comparison with another input method.
This is a research study, not an issue-tracker QA task.
Before recruitment: 1. freeze protocol and hypotheses/analysis; 2. obtain the required institutional/local ethics determination; 3. prepare informed consent; 4. define data retention/withdrawal; 5. version the software/test task; 6. decide what will and will not be shared publicly.
Current ACM venues require authors to explain the relevant ethics/review context for human-participant work and comply with their research environment's requirements. Do not collect publication-intended human data first and ask the ethics question afterward.
Platform validation matrix¶
The programme should eventually cover these distinct environments, because "Linux" or "Windows" alone hides the relevant differences.
| Bucket | Why it matters | Automated | Real hardware |
|---|---|---|---|
| Windows 11, normal Python/source install | camera + native pointer path | E1 | E3/E4 |
| Windows packaged/frozen build | camera capability/packaging differences | static | E3 |
| macOS Apple Silicon | camera permission + native pointer | E1 | E3/E4 |
| Ubuntu GNOME Wayland | portal pointer + Wayland target limits | E1 partial | E3/E4 |
| KDE Plasma Wayland | different portal/compositor behavior | E1 partial | E3/E4 |
| Linux X11 | existing gaze target + X11 pointer path | E1 partial | E3/E4 |
| HiDPI 150/200% | logical/physical coordinate conversion | synthetic | E3 |
| multi-monitor | topology/calibration invalidation | synthetic | E3 |
| integrated webcam | common user path | no | E3/E4 |
| external USB webcam | device/topology variation | no | E3/E4 |
A contributor does not need to test every bucket. Each small issue should ask for one bucket.
Capability evaluation scripts¶
Gaze routing task¶
One trial: 1. show 4 large target panes/regions; 2. prompt "look at target N"; 3. user triggers the normal gaze-routing moment; 4. record intended target and resolved outcome.
Record: - correct; - wrong target; - fallback/no-route; - confidence bucket; - calibration age; - trial time.
Recommended QA block: 40 trials (10/target) after practice.
Primary metric: correct / all intended trials.
Also report wrong-target and fallback separately; fallback is safer than wrong-target and must not be collapsed into one "error".
Head-Pointer task¶
Use large generated targets so the task does not depend on private desktop content.
For each target: - target center; - target width; - pointer start; - movement start/end; - click outcome.
Record: - completion; - movement time; - miss/overshoot; - accidental click; - pauses/recenters; - tracking losses.
For research, the same data can support standard pointing analyses such as Fitts-style throughput, but the analysis plan must be frozen before using that as a paper outcome.
Face-switch task¶
Run blocks: - deliberate gesture block; - neutral/no-action block; - normal speaking block when mouth gestures are tested.
Record: - requested activation count; - detected count; - misses; - extra/false activations; - duration; - activation latency; - gesture name; - configured thresholds/hold/refractory.
Primary safety metric: false activations/hour, not only classifier accuracy.
Hands-free workflow task¶
Use a fixed, non-sensitive demo application/fixture.
Example: 1. focus a text field; 2. dictate a short provided phrase; 3. move to a large button; 4. commit; 5. trigger a safe navigation command; 6. simulate camera loss; 7. pause; 8. resume; 9. finish task.
Record: - task completion; - total time; - number of recovery actions; - number/type of fallbacks; - unintended actions; - whether keyboard/mouse intervention was required.
Replication structure¶
A result must identify a replication cell:
software version
× OS/session
× computer
× camera
× display topology
× person/session (when human)
× feature/config
Do not report "n=10 tests" when all 10 are the same person on the same laptop unless the claim is explicitly about repeated sessions.
For human studies, distinguish: - participants — independent people; - sessions — repeat observations; - trials — repeated actions inside a session.
Never treat 400 gaze trials from one person as n=400 participants.
What can be automated vs what cannot¶
| Question | Automatic? |
|---|---|
| algorithm/state transitions | yes |
| optional import/lazy loading | yes |
| schema/privacy redaction | yes |
| OS import/build compatibility | yes |
| synthetic false activation | yes |
| real camera opens | no, needs device |
| OS permission UI works | real OS/device |
| real gaze accuracy | human + camera |
| real head-pointer control | human + camera |
| false activations during natural behavior | human |
| fatigue/comfort | human report |
| useful hands-free workflow | human task |
Failure reporting¶
A failed validation is a valuable result.
Testers select one: - PASS; - FAIL — reproducible; - PARTIAL — some steps work; - BLOCKED — dependency/permission/hardware prevents test.
Do not silently discard failures from paper-quality datasets. The exclusion rule must be written before analysis, and technical invalidation (e.g. wrong version) must be distinguishable from a poor feature result.
Promotion gates¶
Experimental¶
Requires: - E0/E1 green; - E2 traces; - at least one E3 hardware smoke on each claimed platform; - privacy/permission/status complete; - global stop/recovery.
Recommended¶
Additionally requires: - E4 cross-computer evidence; - E5 cross-person evidence; - E6 stability where calibration matters; - false-action metrics; - accessibility/co-design evidence; - all research claims backed by paper-eligible data collected under the appropriate protocol.
Current no-code replication slots¶
The initial community QA matrix is now explicitly replicated:
- Windows: #428 + #429
- macOS: #430 + #431
- GNOME Wayland: #432 + #433
- KDE Wayland: #434 + #438
- X11: #435 + #439
- HiDPI/multi-monitor: #436 + #440
- test/retest same person/computer: #437